Authors :
Dr. Pratik Tak; Dr. Nishith Narendrakumar Shah; Dr. Sudheer Kumar Darji; Gaje Singh
Volume/Issue :
Volume 11 - 2026, Issue 9 - September
Google Scholar :
https://tinyurl.com/3437ymuu
DOI :
https://doi.org/10.38124/ijisrt/26sep1267
Note : A published paper may take 4-5
working days from the publication date to appear in PlumX Metrics, Semantic Scholar, and
ResearchGate.
Abstract :
Background:
(MBBS, MD Radiology); 2(MBBS DMRE, Radiology); 3(MBBS, MD Radiology); 4(MSc. N)
1;2;3;4Goyal Hospital & Research Centre Pvt. Ltd., Jodhpur, Rajasthan, India
Publication Date: 2026/10/02
MRI requires systematic screening for magnetic-field, implant, metallic-object, patient-preparation, and workflow
related risks.
Objective:
To evaluate the modeled effect of a structured 24-item MRI safety checklist on MRI safety compliance and selected
safety-related outcomes.
Methods:
A quasi-experimental pre-intervention/post-intervention framework was modeled using 200 records, with 100
records in each phase. Each checklist item was scored 1 for compliance and 0 for non-compliance, producing a 0–24 total
score. Continuous outcomes were compared using Welch’s independent-samples t-test, with Mann–Whitney U as a
sensitivity analysis; categorical outcomes were examined using Pearson’s chi-square test. Effect size and 95% confidence
intervals were calculated.
Keywords :
Magnetic Resonance Imaging; MRI Safety; Safety Checklist; Patient Safety; Radiology; Compliance; Near Miss; Quality Improvement; Quasi-Experimental Study.
References :
- American College of Radiology. ACR Manual on MR Safety. American College of Radiology; 2024. The 2026 edition is now available and should be checked for the final submission version.
- American College of Radiology. Manual on Contrast Media. American College of Radiology; current online version.
- World Health Organization. Magnetic fields. Environmental Health Criteria 69. Geneva: World Health Organization.
- World Health Organization. Ethics and medical radiological imaging: a policy brief for health-care providers. Geneva: World Health Organization; 2022.
Background:
(MBBS, MD Radiology); 2(MBBS DMRE, Radiology); 3(MBBS, MD Radiology); 4(MSc. N)
1;2;3;4Goyal Hospital & Research Centre Pvt. Ltd., Jodhpur, Rajasthan, India
Publication Date: 2026/10/02
MRI requires systematic screening for magnetic-field, implant, metallic-object, patient-preparation, and workflow
related risks.
Objective:
To evaluate the modeled effect of a structured 24-item MRI safety checklist on MRI safety compliance and selected
safety-related outcomes.
Methods:
A quasi-experimental pre-intervention/post-intervention framework was modeled using 200 records, with 100
records in each phase. Each checklist item was scored 1 for compliance and 0 for non-compliance, producing a 0–24 total
score. Continuous outcomes were compared using Welch’s independent-samples t-test, with Mann–Whitney U as a
sensitivity analysis; categorical outcomes were examined using Pearson’s chi-square test. Effect size and 95% confidence
intervals were calculated.
Keywords :
Magnetic Resonance Imaging; MRI Safety; Safety Checklist; Patient Safety; Radiology; Compliance; Near Miss; Quality Improvement; Quasi-Experimental Study.