Power System Protection


Authors : Manoj S; Bharath Channaveerayya Hiremath; Ashmitha Ravishankar Harahally; Sangeeta Modi

Volume/Issue : Volume 8 - 2023, Issue 5 - May

Google Scholar : https://bit.ly/3TmGbDi

Scribd : https://tinyurl.com/36tup8fz

DOI : https://doi.org/10.5281/zenodo.8049846

Abstract : The reliability and security are major aspects of a power system. However, the fast development in electrical systems makes the protection more complicated and difficult to achieve the desired objective. These relays have many advantagessuch as fast operation. The use of relay protection enhances the reliability and security of the electrical systems. In this paper,an overcurrent relay is modeled using MATLAB/SIMULINK. The overcurrent relay was chosen as it is widely used in fault detection and clearance of power systems and grids. A relay by definition is an electromechanical switch which is used to sense faults in transmission lines and once the fault is detected, sends a signal to trip the circuit breaker. The overcurrent relay in specific operates when the load current goes beyond the pick-up current value. This paper discusses two important types of protections for overcurrent in the power system, i.e., primary protection and backup protection. For primary protection, every line is provided with an overcurrent relay that trips the circuit breaker when the fault occurs as opposed to backup protection where one relay is given for multiple lines which operates with a definite time delay in absence of the primary protection.

Keywords : Overcurrent Relay, Circuit Breaker, Trip, Fault, Primary, Backup.

The reliability and security are major aspects of a power system. However, the fast development in electrical systems makes the protection more complicated and difficult to achieve the desired objective. These relays have many advantagessuch as fast operation. The use of relay protection enhances the reliability and security of the electrical systems. In this paper,an overcurrent relay is modeled using MATLAB/SIMULINK. The overcurrent relay was chosen as it is widely used in fault detection and clearance of power systems and grids. A relay by definition is an electromechanical switch which is used to sense faults in transmission lines and once the fault is detected, sends a signal to trip the circuit breaker. The overcurrent relay in specific operates when the load current goes beyond the pick-up current value. This paper discusses two important types of protections for overcurrent in the power system, i.e., primary protection and backup protection. For primary protection, every line is provided with an overcurrent relay that trips the circuit breaker when the fault occurs as opposed to backup protection where one relay is given for multiple lines which operates with a definite time delay in absence of the primary protection.

Keywords : Overcurrent Relay, Circuit Breaker, Trip, Fault, Primary, Backup.

CALL FOR PAPERS


Paper Submission Last Date
31 - May - 2024

Paper Review Notification
In 1-2 Days

Paper Publishing
In 2-3 Days

Video Explanation for Published paper

Never miss an update from Papermashup

Get notified about the latest tutorials and downloads.

Subscribe by Email

Get alerts directly into your inbox after each post and stay updated.
Subscribe
OR

Subscribe by RSS

Add our RSS to your feedreader to get regular updates from us.
Subscribe