Abstract :
This study evaluates the indoor and outdoor radon gas concentration across various residential environments in
the Jaunpur district of Eastern Uttar Pradesh, India. To assess the potential health hazards associated with this radioactive
gas, solid state nuclear track detectors (SSNTDs), specifically [insert detector type, e.g. LR-115 plastic track detectors], were
utilized in a bare and cup mode configuration. Radon is a colourless and odourless radioactive gas. Radon exists in building
materials and in indoor and outdoor environments. SSNTDs were used with 25 dosimeters for indoor measurements and 25
dosimeters in outdoor to determine the radon concentration in a total of 50 houses in Jaunpur district in Eastern Uttar
Pradesh of India. SSNTD’s technique was used for the present work in selected indoor and outdoor environments of Jaunpur
district. The detectors were mounting for a fixed duration of 90 days. After the exposure period, the detectors were
chemically etched, and the track density was obtained using an optical microscope or G.M. Counter to determine the radon
concentration in Jaunpur district.
Keywords :
Radon Concentration, Indoor and Outdoor, Jaunpur District, SSNTDs, Dosimeter.
References :
- A. Azam, N.P.S. Rana, P. Singh, A.H. Naqvi, D.S. Srivastava. (2000). Radon progeny (WL) concentration studies in different kind of rooms using LR-115 type II plastic track detector, Solid State Nuclear Track Detectors and Applications.
- D.S. Srivastava, A.H. Naqvi, P. Singh, N.P.S. Rana, A. Azam (1993). Radon measurement inside some rooms in the A.M.U. campus using LR-115 type II plastic track detectors, Proc. At Conference-cum Workshop on Radiation Standard and Measurement, B.A.R.C., Bombay. Jan. 4-6, pp. 23-24.
- Cherouati D.E., Djeffali S. and Durrani S.A. (1988). Calibration factor for LR-115 detectors used for measurement of alpha activity from radon. Nucl. Track Radiat. Meas. 15, 583-586.
- Fleischer R.L., Girard W.A., MorgaCampero A., Turner L.G., Alter H.W. and Gingrich J.E. (1980). Dosimetry of environmental radon; methods and theory for low dose integrated measurements. Health Phys. 19, 957-962. 6. Vol 9, pp. 485497.
- D.S. Srivastava, P. Singh, N.P.S. Rana, A.H. Naqvi, A. Azam, T.V. Ramachandran and M.C. Subba Ramu (1995). Calibration factor for LR-115 type II track detector for environmental radon measurements. Nuclear Geophysics (GREAT BRITAIN).
- Frank A.L. and Benton E.V. (1977). Radon dosimetry using plastic nuclear track detector. Nucl. Track Det. 1, 149-179.
- ICRP Publication 50. (1986). Lung cancer Risk from Indoor Exposure to Radon Daughter. Annals ICRP, 17(1).
- Jonsson G. (1988). Indoor Radon Measurement in Sweden with solid state nuclear track detector technique. Health Phys. 54, 271-35.
- Kumar, A., Saxena, A., Rawat, R.B.S. and Sharma, D. (2014). Natural Radioactivity levels in some village in Shahjahanpur Uttar Pradesh, India. (IJRSI), 32 (12), 1-3.
- Ramachandran T.V., Subba Ramu M.C. and Mishra U.C. (1988). Assessment of radiological effect of indoor radon progeny. BARC Report No. 1432.
- Ramachandran T.V., Muralidharan T.S. and Subba Ramu M.C. (1990). Calibration of nuclear track detectors for the measurement of indoor radon and thoron levels. Ind. J. Phys. 64 A, 365-374.
- Ramachandran T.V., Subba Ramu M.C. Variation of equilibrium factor between Radon and its short-lived decay product in an indoor Atmosphere. Nucl. Geophys. 8, 499-503 (1994).
- Rawat, R.B.S., Kumar, A. and Singh, I. (2011). A Comparative study of environmental indoor radon and thoron in Shahjahanpur and Hardoi district of Central Uttar Pradesh. Recent Research in Science and Technology, 3(6), 19-21.
- Subba Ramu M.C., Shaikh A.N., Muraleedharan T.S., Ramachandran T.V. and Nambi K.S.V. (1991). Environmental radon monitoring in India: a plea for national effort. Proc. Natn. Conf. Particle Track in Solids, Jodhpur (India), 9-11 Oct.
- Abu Jarad F., Fremlin J.H. and Bull R. (1980). A study of radon emitted from building materials using plastic track detectors. Phys. Med. Biol. 25, 683-694.
This study evaluates the indoor and outdoor radon gas concentration across various residential environments in
the Jaunpur district of Eastern Uttar Pradesh, India. To assess the potential health hazards associated with this radioactive
gas, solid state nuclear track detectors (SSNTDs), specifically [insert detector type, e.g. LR-115 plastic track detectors], were
utilized in a bare and cup mode configuration. Radon is a colourless and odourless radioactive gas. Radon exists in building
materials and in indoor and outdoor environments. SSNTDs were used with 25 dosimeters for indoor measurements and 25
dosimeters in outdoor to determine the radon concentration in a total of 50 houses in Jaunpur district in Eastern Uttar
Pradesh of India. SSNTD’s technique was used for the present work in selected indoor and outdoor environments of Jaunpur
district. The detectors were mounting for a fixed duration of 90 days. After the exposure period, the detectors were
chemically etched, and the track density was obtained using an optical microscope or G.M. Counter to determine the radon
concentration in Jaunpur district.