Structural Characteristics of a G+14 Precast Building with Floating Columns and Transfer Girders under Seismic Loading


Authors : Shafiq Mohammad

Volume/Issue : Volume 11 - 2026, Issue 9 - September


Google Scholar : https://tinyurl.com/rc7s2um8

DOI : https://doi.org/10.38124/ijisrt/26sep603

Note : A published paper may take 4-5 working days from the publication date to appear in PlumX Metrics, Semantic Scholar, and ResearchGate.


Abstract : : Floating columns are commonly introduced in multistorey buildings to accommodate architectural requirements such as parking areas, entrance halls, commercial spaces, and conference rooms. However, discontinuity in the vertical loadtransfer path can adversely affect the seismic performance of a building. This study investigates the structural response of a G+14 multistorey building with floating columns and transfer girders under seismic loading. Five analytical configurations were considered: a regular building without floating columns, a building with floating columns, a building with floating columns located at the eleventh storey, a building with floating columns and shear walls, and a building with floating columns with modified column dimensions. The models were developed and analyzed using Autodesk Robot Structural Analysis Professional 2016. The response-spectrum method was used to evaluate base shear, storey displacement, storey drift, and fundamental natural period. The results indicate that introducing floating columns increases lateral displacement, storey drift, and the fundamental time period, while slightly reducing base shear because of the reduction in structural mass. The maximum roof displacement increased from 2.9 cm for the regular building to 4.3 cm when floating columns were introduced at the lower level. The corresponding fundamental period increased from 3.02 s to 3.24 s. The provision of shear walls substantially improved the structural response, reducing the roof displacement to 1.7 cm and the fundamental period to 2.48 s. The findings indicate that floating columns should be avoided in high-seismic regions unless suitable lateral-load-resisting systems, such as shear walls, are provided.

Keywords : Floating Column, Transfer Girder, Precast Building, Seismic Analysis, Storey Drift, Storey Displacement, Shear Wall.

References :

  1. Danish, M. J. “Static and Dynamic Analysis of Multi-Storey Building with the Effect of Ground and Intermediate Soft Storey Having Floating Columns.” International Journal for Scientific Research and Development.
  2. Gaddad, K., and Vijapur, V. “Comparative Study of Multi-Storey Building with and without Floating Columns and Shear Walls.” *International Research Journal of Engineering and Technology.
  3. Kini, V., and Rajeeva, S. V. “Seismic Behavior of RC and Steel-Concrete Composite Multi-Storey Building with Floating Columns with and without Shear Walls.” *International Journal of Research in Engineering and Technology.
  4. Meghana, B. S., and Sadashiva Murthy, T. H. “Effect of Floating Column on the Behavior of Composite Multistoried Building Subjected to Seismic Load.” *International Research Journal of Engineering and Technology*, 2016.
  5. Pandey, G., and Jamle, S. “Optimum Location of Floating Column in Multistorey Building with Seismic Loading.” *International Research Journal of Engineering and Technology*, 2018.
  6. Rohilla, I., Gupta, S. M., and Saini, B. “Seismic Response of Multi-Storey Irregular Building with Floating Column,” 2015.
  7. Shrivastava, A., and Patidar, A. “Seismic Analysis of Multistorey Buildings Having Floating Columns.” *SSRG International Journal of Civil Engineering*, 2018.
  8. Ullas, G. D., Annapurna, B. P., and Gopal, D. J. “Analysis of Multi Storied Infilled Frame with Floating Column.” *International Journal of Research and Analytical Reviews*, 2019.
  9. Wahidi, A., and Seshu, D. R. “Seismic Analysis of Multistorey Building with Floating Columns.” *Asian Journal of Civil Engineering*, vol. 17, no. 8, 2016, pp. 1077–1085.
  10. Yadav, S., and Parolkar, R. “Seismic Behaviour of Multistorey Buildings Having Floating Columns.” *International Journal of Civil and Structural Engineering Research*.

: Floating columns are commonly introduced in multistorey buildings to accommodate architectural requirements such as parking areas, entrance halls, commercial spaces, and conference rooms. However, discontinuity in the vertical loadtransfer path can adversely affect the seismic performance of a building. This study investigates the structural response of a G+14 multistorey building with floating columns and transfer girders under seismic loading. Five analytical configurations were considered: a regular building without floating columns, a building with floating columns, a building with floating columns located at the eleventh storey, a building with floating columns and shear walls, and a building with floating columns with modified column dimensions. The models were developed and analyzed using Autodesk Robot Structural Analysis Professional 2016. The response-spectrum method was used to evaluate base shear, storey displacement, storey drift, and fundamental natural period. The results indicate that introducing floating columns increases lateral displacement, storey drift, and the fundamental time period, while slightly reducing base shear because of the reduction in structural mass. The maximum roof displacement increased from 2.9 cm for the regular building to 4.3 cm when floating columns were introduced at the lower level. The corresponding fundamental period increased from 3.02 s to 3.24 s. The provision of shear walls substantially improved the structural response, reducing the roof displacement to 1.7 cm and the fundamental period to 2.48 s. The findings indicate that floating columns should be avoided in high-seismic regions unless suitable lateral-load-resisting systems, such as shear walls, are provided.

Keywords : Floating Column, Transfer Girder, Precast Building, Seismic Analysis, Storey Drift, Storey Displacement, Shear Wall.

Paper Submission Last Date
31 - October - 2026

SUBMIT YOUR PAPER CALL FOR PAPERS
Video Explanation for Published paper

Never miss an update from Papermashup

Get notified about the latest tutorials and downloads.

Subscribe by Email

Get alerts directly into your inbox after each post and stay updated.
Subscribe
OR

Subscribe by RSS

Add our RSS to your feedreader to get regular updates from us.
Subscribe